Reverse osmosis system
GENO-OSMO-X
Order no. 134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
16
4 | Appropriate application
The reserve osmosis system is designed for the demineralisa-
tion of drinking water according to the German Drinking Water
Ordinance (TrinkwV). The generated water is primarily used for
industrial applications.
A corresponding pre-treatment is required and the application
limits (paragraph 5) must be adhered to.
Note:
In case of water that does not comply with the stipulations
of the German Drinking Water Ordinance (TrinkwV), a water
analysis is required beforehand.
The continuous permeate capacity is subject to the temperature
and was defined at 15°C. The permeate capacity decreases by
up to 3 % per degree centigrade of the feed water temperature .
Note:
This reverse osmosis system adjusts the permeate capac-
ity automatically subject to the temperature. The recovery (con-
centrate to drain) as well as the concentrate recirculation are
adapted to the modified permeate capacity.
The system is adjusted to the permeate requirements to be ex-
pected at the installation site, it is not suitable for major deviations.
The system may only be operated if all components are installed
properly. Safety devices and equipment must NEVER be re-
moved, bridged or tampered with.
Appropriate application of the device also implies that the infor-
mation contained in this operation manual and all safety guide-
lines applying at the installation site be observed. Furthermore,
the maintenance and inspection intervals have to be observed.
4.1 System idle time
If the system is out of operation for more than 14 days, it must
be preserved by Grünbeck's technical customer service/author-
ised service company. The maximum time, the system can re-
main in the preserved condition is 6 months.
In case the down time is longer, the system must be preserved
again in regular intervals by Grünbeck's technical customer ser-
vice/authorised service company. Prior to resuming operation,
the preserving agent must be flushed from the system.