Reverse osmosis system
GENO-OSMO-X
Order no.
134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
49
Parameters
Factory
setting
Setting
range
Comment
Function RO1V4/V7
RO1V4
RO1V4
RO1V7
constant
RO1V4
= First permeate
RO1V7
= Draining of bypass
Constant =
output continu-
ously produces 24 V DC.
Switching capacity max. 5 W
Function
programmable output
Operation
Operation/
dry-run pro-
tection
Operation
= contact closes
upon start of RO1P1
Dry-run protection
= contact
opens if BB1CL4 is undershot
and closes if BB1CL3 is ex-
ceeded.
Redundancy
RO1P2/RO1P3 (*)
No
No/Yes
If two dosing pumps are
present
No
= the pumps have differ-
ent dosing purposes
Yes
= the pumps have the
same dosing purpose and
work redundantly
Operating duration in
case of redundancy
6 h
1…9 h
Dosing, ope
flushing (*)
No
If dosing is se-
lected as pre-
treatment P2
No/P2/P3/
both
The dosing pump either only
runs during the permeate pro-
duction or in addition during
the flushing at the end of pro-
duction:
No
= dosing only during per-
meate production (one or two
dosing pumps)
RO1P2
= two dosing pumps
are present and P2 also runs
during flushing
RO1P3
= two dosing pumps
are present and P3 also runs
during flushing
Both
= two dosing pumps are
present and both also run
during flushing
Pulse division
RO1P2/RO1P3
1
1 ... 99
Settings for antiscalant
(valid for both pulse outputs)
MT 4010: 1
MT 4000: 10
Output logic
Volt.-free contact
Warning
NOC
NOC/
NCC
Switching behaviour of signal
contact terminals 8/9:
NCC
= contact opens in case
of Mains Off or in case a sig-
nal occurs
NOC
= contact closes if a sig-
nal occurs