Reverse osmosis system
GENO-OSMO-X
Order no.
134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
35
By tapping on "START", the feed water solenoid valve, the con-
trol valve concentrate to drain and sporadically the control valve
concentrate recirculation open. The preservation agent is
washed out to the drain.
Attention!
While the preserving agent is being flushed off, the
system is deaerated at the same time. When skipping or prema-
turely aborting the step "flushing" and putting the system in oper-
ation, there are the following two risks
High-pressure pump is running dry.
The preserving agent gets into the permeate tank or into the
permeate line provided by others on site - these can only be
cleaned/flushed with difficulty.
Note:
The flushing of the system can be restarted manually. Re-
fer to chapter F-4.1: To do so, select the operating mode "flush-
ing".