Reverse osmosis system
GENO-OSMO-X
Order no.
134 750 927-inter Edited by: phar/mrie G:\BA-750927-inter_134_GENO-OSMO_X.docx
11
Feed water inlet
BL1
Connection 1“ or 1¼ (male thread), flat sealing, for feed water
connection by others on site
Note:
Provide connection by means of water meter screw con-
nection.
Solenoid valve
for feed water
RO1V1
During the permeate production, this valve is always open. Fol-
lowing the system stop (tank full), the valve remains open for
the programmed flushing volume of the membrane(s).
Fine filter
RO1F1
Pre-filtration of the feed water incl. pressure reducer (pre-set)
4.0 bar and integrated pressure gauge for feed water pressure.
Flow sensor
feed
RO1CF2
Via pulse signal to the control unit.
Feed = Concentrate recircu Pe Concentrate to
drain.
Pressure switch for
minimum pressure
RO1CP1
To prevent the high-pressure pump from running dry. Switches
time-delayed after opening the solenoid valve for feed water.
Flow sensor
feed water
RO1CF1
Via pulse signal to the control unit.
Feed water = Pe Concentrate to drain.
Adjusting valve concen-
trate to drain with drive
RO1V3
To automatically adjust the volume flow concentrate to drain (re-
covery). During the permeate production, this portion of the wa-
ter flow permanently flows to the drain. The volume flow is sub-
ject to the system size. In case of tank "full" as well as in case of
a system failure, the valve always opens the entire cross section
in combination with the solenoid valve for feed water.
Pressure reducer
concentrate
RO1H4
To improve the regulation accuracy of the adjusting valves (set
to 6 bar)
Adjusting valve
concentrate recirculation
with drive
RO1V2
For automatic adjustment of the volume flow concentrate recir-
culation. The volume flow is subject to the system size.
Sampling valve
concentrate
RO1H1
Allows manual quality determination via sampling valve.
Connection concentrate
to drain
BL2
1“ male thread, flat sealing
Note:
Provide for connection via water meter screw connection.
Permeate connection
BL3
1“ male thread, flat sealing
Note:
Provide for connection via water meter screw connection.
High-pressure pump
RO1P1
Centrifugal pump system (frequency-controlled) that generates
the operating pressure required for the membrane. Pump oper-
ates upon permeate demand from the level control located in the
permeate tank. By means of the frequency converter, the
pump's revolution speed is adapted in a way that the nominal
permeate capacity is achieved.
1
2
3
4
5
6
7
8
9
10
11
12
13