System Setup -- Diagnostics
Instructions
Diagnostics
NOTE:
D
The diagnostic information that appears on the
keypad screen
refers to the control module the
keypad is connected to only
, except when using
the CAN diagnostics.
D
Any fluids dispensed while doing diagnostics will
not be tracked and will not be included in the sys-
tem inventory information.
1. Move the cursor to DIAGNOSTICS using the
#
key.
2. Press ENTER on the keypad.
3. The DIAGNOSTICS screen will appear, with the
cursor at ABOUT.
4. Scroll to the option that you want to select by
pressing the
#
or
"
key. Press ENTER to display
that screen option.
5. The ABOUT screen will display information about
the software. Pressing any key will return the
cursor to the DIAGNOSTICS screen.
6. The POWER UP screen will tell how many times
the board has been powered up since the last
software upgrade. Pressing any key will return the
cursor to the DIAGNOSTICS screen.
7. The SOLENOIDS screen allows you to check the
operation of the solenoids by turning them off and
on.
CAUTION
When activating solenoids, fluid may be dispensed.
You are only testing the solenoids that are con-
nected to the control module the keypad is con-
nected to.
LO indicates the solenoid is off. To turn it on, press
the
#
or
"
key and LO will change to HI. Press EN-
TER to turn the solenoid on. The cursor will move
to the next solenoid designation.
Scroll to LO and press ENTER to turn the sole-
noid(s) off again.
Continue to test the solenoids as needed.
Any solenoids that are turned on while using the
SOLENOIDS screen should be turned off before
exiting the screen.
Press the BACK key to go back to the DIAGNOS-
TICS screen.
Screens
_ _ _ _ _ _ _ _ _ _
"
SETUP
A
_ _ _ _ _ _ _ _ _ _
PRINT SETUP
"
UPDATE TABLES
DIAGNOSTICS
DIAGNOSTICS Screens
_ _ _ _ _ _ _ _
"
DIAGNOSTICS
A
_ _ _ _ _ _ _ _
ABOUT
POWER UP
SOLENOIDS
#
_ _ _ _ _ _ _ _
"
DIAGNOSTICS
A
_ _ _ _ _ _ _ _
METERS
"
KEYPAD
DIP SWITCHES
#
_ _ _ _ _ _ _ _
"
DIAGNOSTICS
A
_ _ _ _ _ _ _ _
CLEAR PRINTER BUF.
"
CAN
TRANSACTIONS
#
ABOUT Screen
HORIZON X.XX
FIRMWARE CKSUM: XXXX
DATA
CKSUM: XXXX
USE ANY KEY TO CONT.
POWER UP Screen
THE BOARD WAS
POWERED UP
X TIMES
USE ANY KEY TO CONT.
SOLENOIDS Screen
_ _ _ _ _ _ _ _
"
SOLENOIDS
A
_ _ _ _ _ _ _ _
1
2
3
4
5
6
LO
LO
LO
LO
LO
LO
USE BACK KEY TO EXIT