308607
15
Cable Routing and Connection
7. Route the Solenoid and Meter Cables
to their Assigned Control Module
8. Connect the Solenoid and Meter
Cables
f.
Connect the solenoid cables as shown in Fig.
6. The cables connect at the solenoid end with
wire nuts.
g. Connect the Ready Light as shown in Fig. 6.
h. Connect the pulse meter cables. The cables
connect at the pulse meter end with wire nuts.
D
Connect an oil meter as shown in Fig. 7.
D
Connect an anti-freeze meter as shown in
Fig. 8. Be sure to install the RC Filter.
Fig. 6
06577
P8 or P9
Solenoid Connection
¡
¢
©
¡
Use bulk Cable P/N 113557 (500 ft. [152.5 m]) or 113558
(1000 ft. [305 m)]); 50 ft. (15.3 m) maximum length
©
Ready Light Kit 238996
NOTE:
If existing Ready Light is used, the bulb and lens must
be replaced with bulb P/N 113859 and lens 113857
¢
Fluid Solenoid P/N 218588 (includes Ready Light), 215487 or
512927; Air Solenoid P/N 215407 or 512926
NOTE: See Fig. 9, page 16, for connector locations.
Fig. 7
06579
J5
P5
Pulse Meter P/N 238618 Connection
ground
signal
+12V
black
white
red
©
¡
Connector J5 in this drawing; can be J5, J6, or J7
©
Use bulk Cable P/N 113555 (500 ft. [152.5 m]) or
113556 (1000 ft. [305 m)]); 50 ft. (15.3 m) maxi-
mum length
¢
Pulse Meter P/N 238618
¢
ground
signal
signal
ground
+12V
shield
+12V
shield
black
white
red
Circuit Board
¡
Fig. 8
06580
Pulse Meter P/N 215474 Connection
¡
P5
shield
black
red
©
¡
Connector J5 in this drawing; can be J5, J6, or J7
©
RC Filter P/N 113837; included with meter
¢
Pulse Meter P/N 215474
NC=No Connection
¢
N/C
N/C
black
red
ground
signal
N/C
ground
signal
Summary of Contents for Horizon Fluid Management Systems
Page 81: ...308607 81 Appendix...
Page 97: ...308607 97 Blank Forms...