![Gotting HG G-71915 Device Description Download Page 57](http://html1.mh-extra.com/html/gotting/hg-g-71915/hg-g-71915_device-description_2247539057.webp)
Device Description HG G-71915ZA | English, Revision 01 | Date: 09.09.2021
57
Troubleshooting – Chapter 14
14.2 Error Codes (LEDs)
If an error occurs, all LEDs flash red cyclically. This can be used to indicate the fol
-
lowing error situations.
A list of all status outputs of the antenna via the bus telegrams and the service inter
-
face can be found in Table 9 on page 38.
5.
–
No CAN communication
–
CAN error (indicated via
LEDs, see 14.2 below)
1.
CAN+ interchanged with
CAN-.
2.
Wrong CAN protocol
selected
3.
Wrong parameters for
CAN protocol selected
4.
Internal processor error
1.
Check the corresponding con
-
nections
2.
Set the correct protocol or
parameters using a PC and the
service interface
3.
Hardware defect, please contact
the support of Götting KG
6.
Parameter error (indicated
via LEDs, s. 14.2 below)
1.
Voltage failure during
save attempt
2.
Internal processor error
3.
Try to save the parameters again
4.
Hardware defect, please contact
the support of Götting KG
7.
USB error (indicated via
LEDs, s. 14.2 below)
Internal processor error
Hardware defect, please contact the
support of Götting KG
8.
Error internal time base
(indicated via LEDs, s. 14.2
below)
Table 45
LEDs: Blink codes for errors
Flashing sequence *) Meaning
Diagnossis/Remedy
——
CAN error
s. Table 44 above
-
——
Parameter error
-
-
——
USB error
-
-
-
——
Error internal time base
*)
–
= The LEDs light up red for 200 ms
–
- = short pause 300 ms
–
—— = long pause 1000 ms
Table 44
Error table (part 2 of 2)
Error
Possible cause(s)
Possible Diagnosis/Remedy