![Gotting HG G-71915 Device Description Download Page 36](http://html1.mh-extra.com/html/gotting/hg-g-71915/hg-g-71915_device-description_2247539036.webp)
Device Description HG G-71915ZA | English, Revision 01 | Date: 09.09.2021
36
Chapter 9 – Configuration of the System via the Service Interface
9.2.5 3: Program Transponder
Figure 20
Menu: Program Transponder
Transpondercode dec: decimal input of the new transponder code.
Transpondercode hex: hexadecimal input of the new transponder code.
The programming process is started after entering the new transponder code by
pressing the
(ENTER) key.
9.2.6 4: Data Logging
Figure 21
Menu: Data Logging
For diagnostic purposes, the following values can be output via the service interface.
Via the terminal program, the values can be saved in
CSV-Format
(Comma Sepa
-
rated Values; text file specially formatted for reading into spreadsheets). The follow
-
ing data are recorded:
Timer [ms], level sum signal, level difference signal, code reading sum signal valid,
code reading difference signal valid, code reading total valid, timer posipulse, tran
-
sponder code sum signal, transponder code difference signal, issued transponder
code.