![Gotting HG G-71915 Device Description Download Page 33](http://html1.mh-extra.com/html/gotting/hg-g-71915/hg-g-71915_device-description_2247539033.webp)
Device Description HG G-71915ZA | English, Revision 01 | Date: 09.09.2021
33
Configuration of the System via the Service Interface – Chapter 9
Figure 16
Level for Sum and Diff depending on the position of the transponder under the an
-
tenna
9.2.2 1: Reader Config
Figure 17
Menu: Reader Config
Threshold: Minimum threshold for the sum signal for transponder evaluation.
The default value of 150 has proven itself in test series and should only be changed
in special cases. A value that is set too high (maximum value = 999) reduces the read
range. A value that is selected too low leads to interference.
Posipuls Length: Duration of the PosiPulse in milliseconds.
LEDs: Activation or deactivation of the optical signaling via the LEDs.
If an error is present, it is always output in the form of flash codes in red color, re
-
gardless of this setting (see section 14.2 on page 57).
c
-2047
2048
4095
0
0
X
Sum
Direction of movement of the transponder
Lev
el
Diff