PRO-series Model C3 Conductivity Transmitter
Rev. 0-201
10
T A B L E O F C O N T E N T S ( c o n t i n u e d )
SECTION 3
TRANSMITTER CONFIGURATION
3.1 Selecting LANGUAGE to Operate Transmitter...................................... 34
3.2 Configuring Sensor Characteristics:
SELECT MEASURE (conductivity, resistivity or TDS) ................34-35
Select DISPLAY FORMAT ..........................................................35-36
SET FILTER Time............................................................................ 36
Select Temperature COMPENSATION.......................................36-37
CONFIG TDS Measurement
(not needed for other measurements) ...................................37-38
CONFIG LINEAR Temperature Compensation (config-
uration not needed for other compensation methods) ...........38-39
ENTER NOTE (top line of MEASURE screen)............................39-40
SELECT CELL K (sensor’s GLI-certified “K” value) ....................40-41
Select TEMP ELEMENT Type ....................................................41-42
SET T FACTOR (sensor’s GLI-certified “T” factor) .....................42-43
3.3 SET
°
C OR
°
F (temperature display format) ......................................... 43
3.4 Configuring Analog Output:
SET PARAMETER (representation) ................................................ 44
SET 4 mA and 20 mA VALUES (range expand) .........................44-45
SET FILTER Time............................................................................ 45
SET FAIL LEVEL Mode (off, 4 mA or 20 mA) .................................. 45
3.5 SET PASSCODE (feature enabled or disabled) ................................... 46
3.6 Configuration Setting Summary (ranges/choices and defaults) .......47-48
SECTION 4
TRANSMITTER CALIBRATION
4.1 Important Information .......................................................................49-50
4.2 ZERO Procedure (first-time sensor calibration only)........................50-51
4.3 DRY-CAL Method (highly recommended):
SELECT CELL K (sensor’s GLI-certified “K” value) ....................51-52
SET T FACTOR (sensor’s GLI-certified “T” factor) .....................52-53
4.4 1 POINT SAMPLE Method (wet calibration).....................................53-56
4.5 Analog Output Calibration ................................................................56-57
SECTION 5
TEST/MAINTENANCE
5.1 STATUS Checking (transmitter and sensor) ....................................58-59
5.2 HOLD OUTPUT..................................................................................... 59
5.3 OUTPUT Test Signal........................................................................59-60
5.4 Firmware (EPROM VERSION) Checking .............................................. 60
5.5 SELECT SIM Measurement .............................................................60-61
5.6 SIM SENSOR Setting............................................................................ 61
5.7 RESET CONFIGURE Values to Factory Defaults............................61-62
5.8 RESET CALIBRATE Values to Factory Defaults .................................. 62