Mounting and operating instructions
MovCon
Endurance test Open/Close (moving continuous)
OFF
ON-FLT
ON-PRM
OFF
OExMAN
Acceptance of opening commands after a manual door opening (only if APuGo = OFF)
(opening element inside/outside manual)
OFF
ON
OFF
OEOSIR
Safety device on opposite side to door hinge as opening element.
Note: This parameter must be set to OFF for teaching-in of the LZR-FLATSCAN.
OFF
ON
OFF
PSKIZe
Zero position of the program setting (operating mode); fixed program position that can only
be changed by means of the terminals on the control unit (program selector key in the side
cover inactive).
Use for external program switch (only four terminals) or for controlling the program positions
via the terminals on the control unit.
(program selection terminal zero)
No Act
PSOpen
PSHand
PSAuto
PSExit
PSNigt
No Act
SCBloc
Lock the program selector key in the side cover (side cover block)
Toggle = Lock/unlock (press active program key during at least 5 seconds).
Time = Lock (automatically after 5 minutes without any activation of the program keys), unlo
-
cking (press active program key during at least 5 seconds).
OFF
Toggle
Time
OFF
Buzzer
The buzzer signals the door leaf movement (persons with amblyopia/without hindrance)
OFF
BOTH
OPEN
CLOSE
OFF