FD 10
0549-990-01---10a_2019.11.indd
PUSH
PULL
D
!
0549-990/02a
Page 13 of 69
Mounting and operating instructions
4 MOUNTING
4.1 General
Attention:
It is recommended that a door leaf stop piece be mounted by the customer.
This stop piece prevents the door leaf from being damaged in the manual operating
mode.
Attention:
Check the free running movement of the door leaf. Should it fail to move smoothly and
silently, or if it is out of balance (i. e. it opens or closes by itself), these problems must
be eliminated first!
Warning:
The fastening bases must provide sufficient solidity. If necessary they have to be rein
-
forced by the appropriate means.
Attention:
The maximum admissible undulation of the fastening base is 1 mm. The drive me
-
chanism must be fastened without torsion and perpendicularly, using all the six fixing
holes!
4.2
Mounting versions
Note:
The output shaft of the drive mechanism is close to the door hinge at all times.
The drive mechanism turns in one direction only. It must rotate through 180° (depen
-
ding on the type of installation).