Mounting and operating instructions
5
ELECTRICAL CONNECTIONS
5.1
Power supply
Warning:
Electric shock hazard! Before working on the drive mechanism, completely disconnect
the local mains power supply and block it to prevent accidental or unauthorised reac
-
tivation. Ensure also that country-specific regulations are observed. The mains power
supply must meet the following requirements: 230 VAC (+10/-15 %), 50 Hz, 10/13 A.
Procedure:
1. Guide the power connection termi
-
nal (B) of the drive module through the
protection shield (A) and attach on the
side cover (C).
Phase L
(black/brown)
Earth conduc. PE
(green/yellow)
Neutral cond. N
(blue)
2. If required: Break out the pre-perfora
-
ted flaps (D) on the side cover (C).
3. Connect the mains cable (E) and fit the
strain relief clamp (F).