FD 10
0549-990-01---10a_2019.11.indd
A
6 Nm
B
0549-990/02a
Page 23 of 69
Mounting and operating instructions
4.7
Adjusting the internal open position stop piece
Procedure:
1. Loosen (but do not remove) the three screws (A) on the open position stop piece (B).
Note:
If the open position stop piece (B) sticks, gently tap the screw heads to loosen it.
2. Swivel the door leaves into their desired opening position (external open position stop piece,
maximum opening angle).
3. Push the open-position stop piece (B) as far as it will go, and tighten all the screws (A): Tigh
-
tening moment
6 Nm
.