98
Troubleshooting
Model: WOG-MP-VH
7.01
Temperature Control System - continued
Problem
Probable Cause
Corrective Action
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
Continuous tone alarm sounding
•
“
MISSING FILTER”
message
(Computer) or Light
ON
(Mnaual)
A. Baffle Filter missing
Check, install Baffle Filter
B. Baffle Filter misaligned
Check, reinstall, or properly align
Baffle Filter
C. Charcoal Filter missing or mis-
aligned
Check, reinstall, or properly align
Charcoal Filter
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
posi-
tion
•
Heat Light is
OFF
•
Beeping tone alarm sounding
(Manual)
•
“CLEAN THE EAC”
message
(Computer)
•
CHECK/WASH
lights
ON
A. EAC Cell is excessively dirty
Clean the EAC Cell
B. EAC Cell has bent fins, or shorted
Repair EAC Cell
C. EAC Cell has too many broken ioniz-
er wires
Replace ionizer wires on Cell
D. Poor connection with Contact
Board; dirty or damaged
Clean contacts, or replace board
E. EAC Power Supply is faulty
Replace Power Supply
F. EAC Shutdown Module is faulty
Replace Module
G. EAC Cell is missing
Install or reinstall EAC Cell
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
High Limit Light is
ON
A. Power surge
Cycle Power Switch
OFF
for approx 5
secs, return to
[ON]
B. Low oil level
Check level, add oil as needed
C. Contactor sticking
Check/replace Contactor
D. High Limit Safety Board is faulty
Check/replace High Limit Board
E. High Limit Sensor is faulty, or out of
position
Check, adjust, or replace sensor
E. Controller is faulty
Check/replace Controller
FRYER WILL NOT HEAT:
•
Power Light is
ON
•
Selector Switch is in
[COOK]
position
•
Heat Light is
OFF
•
Constant tone alarm sounding
(Manual)
•
“CLOGGED FILTER”
message
(Computer)
A. Charcoal Filter clogged
Replace Charcoal Filter
B. Vacuum Switch requires adjust-
ment, or is faulty
Adjust Switch, replace if needed
C. Vacuum lines clogged or kinked
Check tubing clean, or remove kinks
D. Fan running too slow
Check voltage
E. Fan clogged with grease film
Clean fan
Summary of Contents for WOG-MP-VH
Page 3: ......
Page 7: ...vi Model WOG MP VH Table Of Contents ...
Page 15: ...4 Model WOG MP VH Introduction ...
Page 23: ...12 Model WOG MP VH Overview 1 2 5 6 7 3 4 Hidden 3 01 Cooking Vat ...
Page 25: ...Model WOG MP VH Overview 14 1 2 3 8 4 7 5 6 3 02 Control Panel Computer Controller 4 1 4 2 9 ...
Page 29: ...18 Model WOG MP VH Overview Hidden 3 03 Lower Cabinet Inside 2 3 7 5 6 4 1 ...
Page 31: ...20 Model WOG MP VH Overview 3 04 Filter Pan Assembly 3 4 1 2 5 6 ...
Page 33: ...22 Model WOG MP VH Overview Not Shown 3 05 Ventless Hood 2 3 7 5 6 4 1 ...
Page 39: ...28 Model WOG MP VH Overview ...
Page 45: ...34 Model WOG MP VH Pre Operation ...
Page 99: ...88 Fryer Operation Model WOG MP VH ...
Page 107: ...96 Cleaning Model WOG MP VH ...
Page 115: ...104 Parts List Model WOG MP VH Not shown 8 03 Front Lower Cabinet 2 1 3 4 5 6 7 8 9 10 ...
Page 117: ...106 Parts List Model WOG MP VH Not shown 8 04 Rear Lower Cabinet 2 1 5 3 4 ...
Page 119: ...108 Parts List Model WOG MP VH 8 05 Cooking Vat 1 5 3 4 2 3 Not shown ...
Page 121: ...110 Parts List Model WOG MP VH 8 06 Filter Pan Assembly 1 6 3 5 2 4 7 8 9 10 11 ...
Page 123: ...112 Parts List Model WOG MP VH 8 07 Ventless Hood Front 1 5 3 4 2 9 8 10 6 7 Not shown 11 ...
Page 127: ...116 Parts List Model WOG MP VH ...
Page 128: ......