79
Fryer Operation
Model: WOG-MP-VH
CHA
RCO
AL
CHA
RCO
AL
Switch at back of Hood must be
actuated by Filter when installed.
1. Unlatch Filter Access Cover and lift off.
2. Grasp Charcoal Filter and pull straight out, at an slight
upward angle.
Note airflow arrow on
label; blue fiber-fill side UP.
1. Install with blue fiber-fill side facing
UP
.
2. Align in guides, slide straight into Hood.
Front of Filter must be flush with Hood front.
5.07.1.2
Removing and Installing Hood Filters - continued
E. Removing and Installing Charcoal Filter:
5.07.2
Ventless Hood Operation
Be certain that all Hood Filters are properly installed, and that the Filter Access Cover is in place and securely
latched before placing Power Switch in the
[ON]
position.
NOTE:
The appliance will NOT power-up if the Filter Access Cover is missing or ajar. The sides of
the Cover must seat flush against the Hood front and the pin on the right-hand edge must
engage the interlock switch inside the Hood wall.
1
2
1
1. Placing the Fryer Power Switch
①
in the
[ON]
position automatically starts the Hood fan
.
2. A constant tone alarm may sound momentarily and then stop as fan speed increases to normal operating range.
3. The E.A.C.
[ON]
Status Light
②
should turn
ON
to indicate that the Electronic Air Cleaner is functioning. Should
any other Status Light turn
ON
there is a potential problem with the E.A.C. Filter system; see
Section 5.07.4
2
Summary of Contents for WOG-MP-VH
Page 3: ......
Page 7: ...vi Model WOG MP VH Table Of Contents ...
Page 15: ...4 Model WOG MP VH Introduction ...
Page 23: ...12 Model WOG MP VH Overview 1 2 5 6 7 3 4 Hidden 3 01 Cooking Vat ...
Page 25: ...Model WOG MP VH Overview 14 1 2 3 8 4 7 5 6 3 02 Control Panel Computer Controller 4 1 4 2 9 ...
Page 29: ...18 Model WOG MP VH Overview Hidden 3 03 Lower Cabinet Inside 2 3 7 5 6 4 1 ...
Page 31: ...20 Model WOG MP VH Overview 3 04 Filter Pan Assembly 3 4 1 2 5 6 ...
Page 33: ...22 Model WOG MP VH Overview Not Shown 3 05 Ventless Hood 2 3 7 5 6 4 1 ...
Page 39: ...28 Model WOG MP VH Overview ...
Page 45: ...34 Model WOG MP VH Pre Operation ...
Page 99: ...88 Fryer Operation Model WOG MP VH ...
Page 107: ...96 Cleaning Model WOG MP VH ...
Page 115: ...104 Parts List Model WOG MP VH Not shown 8 03 Front Lower Cabinet 2 1 3 4 5 6 7 8 9 10 ...
Page 117: ...106 Parts List Model WOG MP VH Not shown 8 04 Rear Lower Cabinet 2 1 5 3 4 ...
Page 119: ...108 Parts List Model WOG MP VH 8 05 Cooking Vat 1 5 3 4 2 3 Not shown ...
Page 121: ...110 Parts List Model WOG MP VH 8 06 Filter Pan Assembly 1 6 3 5 2 4 7 8 9 10 11 ...
Page 123: ...112 Parts List Model WOG MP VH 8 07 Ventless Hood Front 1 5 3 4 2 9 8 10 6 7 Not shown 11 ...
Page 127: ...116 Parts List Model WOG MP VH ...
Page 128: ......