58
Fryer Operation
Model: WOG-MP-VH
5.03.2
Computer Control Fryer - Alarms and Errors
Certain conditions, which can cause unsafe operation or damage to the unit, such as
open valves, low oil level, high temp, etc. will activate error
codes and sound an alarm tone. Error Codes are shown on
the
Lower 7-Segment Display
; error information is shown on
the
Upper OLED Display
. Typically, the heating elements are
disabled until the error condition is corrected. Pressing the
ALARM
key silences the alarm tone, but does not clear the
error. Error Codes are shown on the following Table; details are presented in the
following section.
OLED
7-Segment
ERROR CODE DESCRIPTION (OLED Display)
PROBLEM
OPEN
DRAIN IS OPEN
Drain valve is open, or not completely closed. Basket will be
raised if it is down. Close drain to clear error.
----
CHECK OIL LEVEL, ENSURE VAT IS
FULL, IF FULL THEN PRESS
[START]
This is a secondary error displayed after closing drain clears the
OPEN error; allows confirmation of oil level.
ER07
MAX ELEMENT TEMP – PRESS
[START] (Post Warning)
Error is displayed after MAX element temperature (ER19) has
occurred and the element has cooled below MAX temperature, .
ER13
OIL PROBE Error
Problem with the Variable Oil Temp Probe.
Service technician
required.
ER15
ELEMENT PROBE Error
Problem with the Element Temp Probe, typically attached
directly to heating element.
Service technician required.
ER19
MAX ELEMENT TEMP Error
The maximum heating element temperature has been exceeded.
This is a safety device;
NEVER bypass this Probe.
ER21
BAFFLE FILTER MISSING
Ventless Fryers (VH) Only ...
Baffle Filter is missing, or
improperly installed.
ER22
CHARCOAL FILTER MISSING
Ventless Fryers (VH) Only ...
Charcoal Filter is missing, or
improperly installed.
ER23
FILTER CLOGGED
Ventless Fryers (VH) Only ...
pressure switch is not engaging.
Indicates airflow restriction; Charcoal Filter is clogged, or other
obstructions. Replace Filter, remove obstruction.
ER24
EAC CELL DIRTY
Ventless Fryers (VH) Only ...
EAC Filter Cell is dirty and needs to
be cleaned. Error is also caused by other various conditions.
ER25
GUARD BAND EXCEEDED
Actual oil temperature deviates from setpoint by the Guard Band
amount. Allow oil to cool, or heat, to within range. Factory
default is 900
°
F ...
Error should not occur
.
ER37
EEPROM Error
An error occurred while saving settings to the EEPROM.
Contact
Giles Tech Service (800.554.4537).
ER38
Internal ADC Error
The ADC (Analog-to-Digital Converter) chip that reads output
from thermocouples is not working. MCB1 board must be
replaced.
Contact Giles Tech Service (800.554.4537).
Summary of Contents for WOG-MP-VH
Page 3: ......
Page 7: ...vi Model WOG MP VH Table Of Contents ...
Page 15: ...4 Model WOG MP VH Introduction ...
Page 23: ...12 Model WOG MP VH Overview 1 2 5 6 7 3 4 Hidden 3 01 Cooking Vat ...
Page 25: ...Model WOG MP VH Overview 14 1 2 3 8 4 7 5 6 3 02 Control Panel Computer Controller 4 1 4 2 9 ...
Page 29: ...18 Model WOG MP VH Overview Hidden 3 03 Lower Cabinet Inside 2 3 7 5 6 4 1 ...
Page 31: ...20 Model WOG MP VH Overview 3 04 Filter Pan Assembly 3 4 1 2 5 6 ...
Page 33: ...22 Model WOG MP VH Overview Not Shown 3 05 Ventless Hood 2 3 7 5 6 4 1 ...
Page 39: ...28 Model WOG MP VH Overview ...
Page 45: ...34 Model WOG MP VH Pre Operation ...
Page 99: ...88 Fryer Operation Model WOG MP VH ...
Page 107: ...96 Cleaning Model WOG MP VH ...
Page 115: ...104 Parts List Model WOG MP VH Not shown 8 03 Front Lower Cabinet 2 1 3 4 5 6 7 8 9 10 ...
Page 117: ...106 Parts List Model WOG MP VH Not shown 8 04 Rear Lower Cabinet 2 1 5 3 4 ...
Page 119: ...108 Parts List Model WOG MP VH 8 05 Cooking Vat 1 5 3 4 2 3 Not shown ...
Page 121: ...110 Parts List Model WOG MP VH 8 06 Filter Pan Assembly 1 6 3 5 2 4 7 8 9 10 11 ...
Page 123: ...112 Parts List Model WOG MP VH 8 07 Ventless Hood Front 1 5 3 4 2 9 8 10 6 7 Not shown 11 ...
Page 127: ...116 Parts List Model WOG MP VH ...
Page 128: ......