Troubleshooting
56
8 - 1 Temperature Control System with Cooking Computer
Problem
Probable Cause
Repair Procedure
FRYER HEAT SLOW:
A. Incorrect cooking procedures.
A. Consult operations manual for
(slow recovery) Heat light stays on.
proper cooking procedure.
B. Element failing.
B. Replace bad element.
C. Contactor failing.
C. Replace contactor.
D. Loose wire.
D. Repair loose wire.
E. Low supply voltage.
E. Supply proper voltage.
FRYER HEATS SLOW:
A. Low supply voltage.
A. Supply proper voltage.
(short cycling)
B. Variable probe touching element.
B. Reposition variable probe.
Heat light off and on continuously.
C. Cooking computer faulty.
C. Replace Cooking computer.
OIL TEMPERATURE ERRATIC:
A. Probe bad.
A. Replace probe.
B. Contactor failing.
B. Replace contactor.
C. Temperature controller faulty.
C. Replace temperature controller.
D. Loose wire.
D. Repair loose wire.
OIL SMOKING:
A. Old oil.
A. Change oil.
B. Over temperature.
B. Check temperature control system.
C. Dirty element.
C. Clean elements.
D. Element failure.
D. Replace element.
E. Improper element voltage.
E. Supply proper voltage.
F. Low oil level.
F. Keep oil at oil level line.
Summary of Contents for Chester Fried CF 400
Page 10: ...7 Operating Instructions ...
Page 16: ...13 Fryer Components and Their Function Cooking Vessel Figure 3 3 6 2 1 5 4 ...
Page 29: ...26 Preparing the Fryer for Operation Filter Pan Shown with Drain Hose Attached Figure 7 ...
Page 39: ...36 Preparing the Fryer for Operation Figure 11 VH Series ...
Page 46: ...43 Fire Suppression System 6 6 Illustrations Fire Suppression Plumbing Diagram ...
Page 48: ...45 Fire Suppression System 6 6 Illustrations Fusible Link Conduit Diagram ...
Page 50: ...47 Fire Suppression System 6 6 Illustrations Manual Pull Conduit Diagram ...
Page 52: ...49 Fire Suppression System 6 6 Illustrations Fire Suppression Conduit Diagram ...
Page 79: ...76 Wiring Model CF 400 500 1 3 Phase 10 13 Wiring Schematic ...