30
Preparing the Fryer for Operation
7.
Re-install both parts at the beginning of each day.
8.
CHANGE SOAK TANK SOLUTION AT LEAST MONTHLY by dipping it out and into the sink. NEVER LIFT
THE SOAK TANK TO EMPTY.
9.
Clean the Baffle Filter DAILY by simply spraying and rinsing residue from the filter with HOT water and
letting it dry.
5 - 4 Removal and Replacement of Filters
To Replace the Charcoal Filter or clean the EAC, perform the following steps:
1.
Place the Ventless Hood System’s Power Switch in the “OFF” position.
WARNING
Failure to ensure the Selector Switch is in the “OFF” position during the procedure,
may result in equipment damage, electrical shock and/or personal injury.
2.
Release the catch which secures the access panel located on the lower front portion of the hood system.
Remove the access panel.
3.
The Charcoal Filter is located directly above the EAC. Remove the Charcoal Filter by grasping it by the
edge and pulling outward. (See Figures 8 & 10.)
4.
Discard the used Charcoal Filter and install the replacement filter with the blue side facing the EAC.
IMPORTANT NOTE:
Never attempt to clean the Charcoal Filter. Keep a spare filter on hand (part # 30248) for quick change-out
when needed!
5.
Remove the EAC by grasping the handle and pulling outward. (Care should be given not to bend the
fins or break the ionizer wires.)
6.
After cleaning, reinstall the EAC with the ionizer wires facing down.
7.
To remove the Baffle Filter, push the front end of filter upward and slide toward front of the hood. Let
the back end of the filter down and remove filter from hood. (Use Caution when grasping filter by
openings to prevent being cut by sharp edges.)
8.
To replace Baffle Filter, reverse step 7. (Be sure to install filter so interlock arm is activated when the
filter is in place. Failure to do so will prevent the appliance from operating.)
!
Summary of Contents for Chester Fried CF 400
Page 10: ...7 Operating Instructions ...
Page 16: ...13 Fryer Components and Their Function Cooking Vessel Figure 3 3 6 2 1 5 4 ...
Page 29: ...26 Preparing the Fryer for Operation Filter Pan Shown with Drain Hose Attached Figure 7 ...
Page 39: ...36 Preparing the Fryer for Operation Figure 11 VH Series ...
Page 46: ...43 Fire Suppression System 6 6 Illustrations Fire Suppression Plumbing Diagram ...
Page 48: ...45 Fire Suppression System 6 6 Illustrations Fusible Link Conduit Diagram ...
Page 50: ...47 Fire Suppression System 6 6 Illustrations Manual Pull Conduit Diagram ...
Page 52: ...49 Fire Suppression System 6 6 Illustrations Fire Suppression Conduit Diagram ...
Page 79: ...76 Wiring Model CF 400 500 1 3 Phase 10 13 Wiring Schematic ...