55
Troubleshooting
8 - 1 Temperature Control System with Cooking Computer
Problem
Probable Cause
Repair Procedure
FRYER WILL NOT TURN ON:
A. Not connected to power source.
A. Connect to proper power source.
No power light.
B. Bad fuse or circuit breaker.
B. Check fuse or breaker.
C. Fuse holder cracked.
C. Replace fuse holder.
D. Power Switch bad.
D. Replace Power Switch.
E. Improper supply voltage.
E. Connect to proper voltage source.
F. Hood Cover not closed.
F. Close Hood cover.
G. Fire Suppression not armed.
G. Call local Ansul Dealer to arm.
H. (Los Angeles only) “HOLD to
H. Hold down “HOLD to
START” button not held down
START” button for 5 seconds.
for 5 seconds.
FRYER WILL NOT HEAT:
A. Selector Switch not in cook
A. Place selector to switch in Power
Power light on. Heat light not on.
position.
“COOK” position.
FRYER WILL NOT HEAT:
A. Selected menu key programmed
A. Set temperature controller to
Power light on.
below present oil temperature.
desired temperature.
Selector Switch in cook position.
B. Drain valve open.
B. Close drain valve.
Heat light not on.
C. Cooking computer faulty.
C. Replace Cooking computer.
D. Variable probe shorted or open.
D. Replace probe.
E. Loose wire.
E. Repair loose wire.
F. Contactor failure.
F. Replace faulty contactor.
G. Element bad.
G. Replace element.
H. Selector Switch bad.
H. Replace Selector Switch.
FRYER WILL NOT HEAT:
A. Power surge.
A. Turn Power Switch off for 5 sec.
Power light on.
B. Plug not completely in.
B. Reconnect to power source.
Selector Switch in cook position.
C. Oil level too low.
C. Fill to kettle oil level mark.
High Limit light On.
D. Sticking contactor.
D. Replace contactor.
E. Bad high limit board.
E. Replace high limit board.
F. High limit probe short or open.
F. Replace High limit probe.
G. Line spikes or noise.
G. Filter line or remove noise
source.
Summary of Contents for Chester Fried CF 400
Page 10: ...7 Operating Instructions ...
Page 16: ...13 Fryer Components and Their Function Cooking Vessel Figure 3 3 6 2 1 5 4 ...
Page 29: ...26 Preparing the Fryer for Operation Filter Pan Shown with Drain Hose Attached Figure 7 ...
Page 39: ...36 Preparing the Fryer for Operation Figure 11 VH Series ...
Page 46: ...43 Fire Suppression System 6 6 Illustrations Fire Suppression Plumbing Diagram ...
Page 48: ...45 Fire Suppression System 6 6 Illustrations Fusible Link Conduit Diagram ...
Page 50: ...47 Fire Suppression System 6 6 Illustrations Manual Pull Conduit Diagram ...
Page 52: ...49 Fire Suppression System 6 6 Illustrations Fire Suppression Conduit Diagram ...
Page 79: ...76 Wiring Model CF 400 500 1 3 Phase 10 13 Wiring Schematic ...