CRIND Communication Problems Troubleshooting Encore 700 S CRIND Communication Issues
MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018 Page B-3
Insite360 Encore not receiving
any incremental logs from PCN,
and PCN will not respond to
remote commands such as PCN
reset during a feature test.
Verify that the Z-Modem cable is connected at P315 and on
P1111 at the PCN (excludes E300 and Advantage).
Device is offline in Insite360
Encore
Check Router Enabled D21 LED. If “ON Green”, SSoM is
installed and running; does not mean it is configured
properly. If LED is OFF, replace the assembly.
Check SSoM WebApp configuration.
Ping the SSOMs internal IP address using Laptop Service
port.
Check SSoM software version if connected to FlexPay IV. If
at 1.3.13, SSoM will need to be upgraded to latest version.
Call the Gilbarco Help Desk.
CRIND showing down in the
Insite360 Encore
Check the CAT5 cable connections from DCM2.2 and ping
the CRIND IP Addresses using laptop service port. SSoM
WebApp might be misconfigured.
Error found during SSoM
Registration
Perform “Check Internet” test in SSoM webapp.
Verify the SSoM configuration.
Check physical connections to internal devices and back
room hardware.
Router Enabled LED ON and
SSoM Registration LED blinking
but still device showing offline in
Insite360
Reboot the dispenser manually.
Insite360 Encore is not able to
perform remote warmstart feature
Verify that the Z-Modem cable is connected at P315 and on
P1111 at the PCN.
Ensure that the PCN is at minimum version.
Ensure that the correct power supply cable (M07973A006) is
installed.
Ensure that the power supply meets minimum requirements.
Z-Modem showing Down status
in the Insite360 Encore
Verify that the Z-Modem cable is connected at P315 and on
P1111 at the PCN.
Two-wire showing Down status in
the Insite360 Encore
Check connections P303 on DCM2.2 and P1109 on PCN.
Verify that Jumper J6 is set to 45 mA.
Screen Stuck at the Card Reader
Error Symbol on FlexPay IV
Check CAT5 connections on DCM2.2 and at the card reader.
Check for dismouted card reader and tamper event.
Ping card reader from laptop service port.
Symptom
Potential Causes
Check/Remedy