![GILBARCO VEEDER-ROOT Encore 700 S Start-Up And Service Manual Download Page 47](http://html.mh-extra.com/html/gilbarco-veeder-root/encore-700-s/encore-700-s_start-up-and-service-manual_2227131047.webp)
FlexPay Control Board [FCB (M11930K001)]
Service
MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page 4-17
Board Connections and Cables
The following table lists the connection details:
Connector#
Via Cable
To Board
At Connector#
P411
M10453A001 M07895A001
J301A, J301B
P603
M10453A001 M10371A001
J1
P504
M09259A001
-
-
P502
M06745A003 M04219A001
-
P503
Q13850-06
M07895A001
J312A, J312B
P506
M07957A004 M10206B001,
M10206B002,
M08430B002
-
P402
M07702A016 M08228B001,
M10728B001,
M07895A001
J302A, J302B
P414
M09267A001 M09112A001,
M09232A001
J214
If FCB corrupts, the software recover jumper JP1 allows the FCB to boot from another
duplicate base image. Install JP1 to recover the corrupt FCB (see
).
Figure 4-14: FCB LEDs and Jumper Assignment
SCR
Communication
Pump Communication
(Printer)
FlexPay EPP
Communication
POS Communication
(OTI)
Lost Key
Secure Application
Centric Infrastructure
(ACI)
JP1 Software
Recovery
Open Multimedia Applications
Platform (OMAP) ACT