MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page 3-1
Configuring CRIND
Start-up
3 – Start-up
Configuring CRIND
The CRIND device on each side is programmed individually by inserting the CRIND
Diagnostic Card (Q12534-170) on each side (cannot be done from the same side). In CRIND
diagnostics, you must press
Enter
after each numeric key entry on the FlexPay EPP.
“Side 1” appears irrespective of the side being programmed.
Due to enhanced security of the FlexPay UPT, you must press
Enter
after each key entry
when using CRIND diagnostics.
IMPORTANT INFORMATION
Note: For more information on Encore 700 S Electronics CRIND Basic Input/Output System
(BIOS), refer to MDE-4185 CRIND Encore 700 S Electronics CRIND BIOS
Configuration Interface Manual.
To access CRIND diagnostic programming, proceed as follows:
1
Insert and remove the CRIND diagnostic card.
Note: Card reader is sensitive to light and may not be able to read the card if the door is open.
Close the main doors to eliminate any outside light intrusion.
Figure 3-1: Swiping CRIND Diagnostic Card
CRIND Diagnostic Card (Q12534-170)