Service
MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
Page 4-21
DCM2.2 Jumpers
The following table lists the status and functions of jumpers:
Connector
ON
OFF
Function
J3
X
High-speed connection active. P304 A/B disabled.
X
High-speed connection inactive. P304A and P304B connects to Category
5 (CAT-5) running through the conduit for high speed connection (if used).
J4
X
Unit is connected to a Passport POS MOC
X
Unit is connected to a third party POS (Generic)
J5
X
VLAN is enabled (FlexPay II only)
X
VLAN is disabled
J6
B
Pump communications. Install the jumper on the B position for the
45 mA Current loop.