22 Info and error messages on the display
Instruction Manual BCF Plus
(11.15) BCF Plus_BA_04
40
22 Info and error messages on the
display
The fusion machine has an information and error message system that
provides the operator with information on handling errors and machine faults.
22.1
Handling and machine errors
Error message
Cause
Remedy
Ambient temperature T is either
too low (T<10°C) or too high
(T>40°C)
Make sure the temperature in
the work area remains between
+10°C and +40°C
Fusion number counter in the
machine is defective
! +GF+ Service !
Temperature of heating station is
greater than 70°C
Allow automatic cooling process
of heating station to finish
Pressure sensor in the machine
is defective
! +GF+ Service !
Pressure connection not
closed
Defective
compressor
Check compressed air
connections and hose for
leaks
! +GF+ Service !