Instruction Manual BCF Plus
21 Faults
(11.15) BCF Plus_BA_04
39
21 Faults
Fault
Cause
Remedy
Short shavings are produced
during facing
Facer blades are blunt
Replace or turn facer blades
around
Heating station cannot be
opened after fusion.
Pipes/fittings stick to the
heating element
Heating station is soiled
Heating station was not
closed
Clean heating station
Heavy material extrusion in
the parting lines of the heating
station
Parting lines are soiled
Heating station is warped
(top to bottom part)
Heating station was not
closed
Clean heating station
Replace heating station
Compressor runs several
times (> 3 times) during the
fusion process
Compressed air hose leaks
or the bladder and the
connections
Shorten the compressed air
hose by approx. 10 mm at
both the bladder and
machine sides
Replace bladder
Check/replace
connections
Heating station does not reach
the required fusion
temperature
Defective
fuse
Replace (heating) fuses
(F2/F3)
No log printout
Wrong printer driver
Set to standard ASCII code
for the printer
No Display
Defective
fuse
Wrong contrast settings
Replace the main fuse
Correct the contrast settings
in the menu