Type
Description
Carrier wave
658 nm
Measuring system
System Analyzer Basis 100 MHz - 150 MHz
Distance [m]
Laser dot size, approximately [mm]
at 30
7 x 10
at 50
8 x 20
at 100
16 x 25
8.4
Distance Measurement - Long Range (LO mode)
The range of the long range measurements is the same for A5 and A10.
Reflector
Range A
Range B
Range C
[m]
[ft]
[m]
[ft]
[m]
[ft]
Standard prism
(ZPR100)
2200
7300
7500
24600
>10000
>33000
Range of measurement:
1000 m to 12000 m
Display unambiguous:
up to 12000 m
Range
Description
A
Strong haze, visibility 5km; or strong sunlight, severe heat shim-
mer
B
Light haze, visibility about 20km; or moderate sunlight, slight heat
shimmer
C
Overcast, no haze, visibility about 40km; no heat shimmer
Standard measuring
Standard
deviation
ISO 17123-4
Measure time,
typical [s]
Measure time,
maximum [s]
Long Range
5 mm + 2 ppm
2.5
12
Beam interruptions, severe heat shimmer and moving objects within the beam path can result in
deviations of the specified accuracy. The display resolution is 0.1 mm.
Type
Description
Principle
Phase measurement
Type
Coaxial, visible red laser
Carrier wave
658nm
Measuring system
System Analyzer Basis 100MHz - 150MHz
Laser dot size
Range
Atmospheric conditions
Accuracy
Characteristics
54