Cinterion
®
EHS6 AT Command Set
2.12 AT^SCFG
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 64 of 513
eCall callback timeout in milliseconds
This setting will take effect only after restarting the module.
Input values may be rounded down to the nearest second (e.g. input value "2999999" becomes "2999000" in
read command response.
0...43200000
(D)
...2147483646
Minimum Set of Data for eCall
This parameter sets the Minimum Set of Data (MSD) for eCalls.
The data needs to be specified as hexadecimal encoded string, e.g. "1A13F3". The maximal length of the string
is 280 characters (140 bytes). If the content is shorter, the string will be padded with zeros. Powerup default is
a string of zeros.
Command switch is required for ERA-GLONASS only. The switch restarts the ERA-GLONASS modem in PULL
mode, i.e., to re-establish the eCall without the usual startup phase for outgoing calls. This may be required if a
previous eCall was dropped after the MSD was transmitted successfully. The setting has to be done before the
eCall and will be set automatically back to default after the eCall is released.
“0“
(P)
Disable pull mode.
“1“
Enable pull mode.
eCall session timeout in milliseconds
The session timeout aborts the MSD transmission; the session timer starts when the eCall modem begins to
transmit (i.e., SF) and stops when the MSD is successfully transmitted (at least two LL-ACKs received).
0...20000
(P)
...2147483646
eCall start timeout in milliseconds
The start timer awaits start signal; it starts when the eCall emergency setup is executed and stops when three
valid, consecutive SF and start messages are received.
0...5000
(P)
...2147483646
Emergency call numbers on non-ECC USIM
This parameter specifies emergency call numbers on USIM without ECC field and with empty ECC field. The
parameter has no influence on the commonly used emergency numbers 112 and 911 which are always sup-
ported.
Please refer also to Section
where you can find a list of emergency call numbers supported if no USIM
is inserted.
The value range of
is "0"..."255". To select or deselect an emergency number calculate the sum of the
values of all desired numbers and use the resulting value. For example, for "08" (2) and "118" (8) please enter
the value (10).
Parameter is global for the ME, non-volatile and will not be reset by
.
“ 0“
(D)
No additional emergency numbers
“ 1“
000
“ 2“
08
“ 4“
110
<callbacktimeout>
(str)(NV)
<msd>
(str)
<pullmode>
(str)
<sessiontimeout>
(str)
<starttimeout>
(str)
<ecc>
(str)(+CSCS)(NV)