Cinterion
®
EHS6 AT Command Set
2.12 AT^SCFG
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 70 of 513
“off“
Disable URCs related to Internet service commands.
This requires the TE to employ polling techniques when using the Internet ser-
vice AT commands: The TE is responsible to retrieve all status information
needed to control an Internet session. The method is referred to as polling
mode.
OTAP tracer
This parameter enables a trace output of the Over The Air procedure. The tracer is useful for obtaining additional
information when setting up an OTAP scenario. The output is provided on the interface configured with
(given
has to differ from currently used one) or if omitted (for compatibility reason only) on
the interface on which the command was entered. While the tracer is enabled the interface is used for trace out-
put only, meaning that no AT commands can be entered. The tracer will be switched off only by a reset of the
ME, e.g. after a completed OTAP procedure or if disabled by setting parameter to "0".
“0“
Disable OTAP tracer.
“1“
Enable OTAP tracer.
Current Serial Interface Allocation
Parameter shows the current allocation of the serial interfaces. Configuration may be overwritten by the GPIO
configuration done by the AT^SCFG parameters "GPIO/mode/...".
“0“
(D)
AT commands are usable on ASC0, USB[0345] and USB-HSI[012]; USB1 and
USB2 are reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
Note: This mode is set by default giving you the flexibility to connect to ASC0,
USB and HSIC when starting the ME the very first time. However, in order to
save power, it is not recommended to employ USB and HSIC in parallel. There-
fore, for final application design, we recommend to set either mode 1, 2 or 3.
“1“
AT commands are usable on ASC0, ASC1 and USB[0345]. USB1 and USB2
are reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
“2“
AT commands are usable on ASC0 and USB[01345]; ASC1 and USB2 are
reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
“3“
AT commands are usable on ASC0 and USB-HSI[012]. USB1 and USB2 are
reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
Requested Serial Interface Allocation
Parameter allows to configure the allocation of the serial interfaces. On powerup the requested configuration is
the same as the current configuration. If the requested configuration becomes different to the current configura-
tion, then it becomes active after restart.
“0“
AT commands are usable on ASC0, USB[0345] and USB-HSI[012]. USB1 and
USB2 are reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
Not recommended for final application design (see
above.
“1“
AT commands are usable on ASC0, ASC1 and USB[0345]; USB1 and USB2
are reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
“2“
AT commands are usable on ASC0 and USB[01345]; ASC1 and USB2 are
reserved for tracing by Gemalto M2M GmbH. USB6 is unavailable.
“3“
AT commands are usable on ASC0 and USB-HSI[012]. USB1 is reserved for
tracing by Gemalto M2M GmbH. USB6 is unavailable.
<otapTracer>
(str)(+CSCS)
<curSerialIfcAlloc>
(str)(+CSCS)(NV)
<reqSerialIfcAlloc>
(str)(+CSCS)