Cinterion
®
EHS6 AT Command Set
16.11 AT^SRTC
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 405 of 513
16.11
AT^SRTC Ring tone configuration
The
read command returns the current
and current
. The read command can be
used while test playback is off or on. In the latter case, see execute command for details.
The
execute command is intended only for testing. It starts to play a melody from the audio output cur-
rently selected with
. To deactivate test playback use
again.
During test playback, you can enter the write command to select another melody and adjust the volume. Also,
you can enter the read command to check the type and volume of the current ring tone, and to view the status
of playback (on / off).
The
write command chooses the type and volume of ring tones. The selected
and
are stored non-volatile. The only exception is
=0 which is not stored because it is intended only to quickly
stop the tone currently played. So
=0 only stops immediately the audible ring tone, but does not terminate
the RING URC. In this case the
write command returns only OK.
Syntax
Test Command
AT^SRTC=?
Response(s)
^SRTC:
s, (list of supported)
OK
Read Command
AT^SRTC?
Response(s)
^SRTC:
,
OK
ERROR
+CME ERROR:
<err>
Exec Command
AT^SRTC
Response(s)
OK
ERROR
+CME ERROR:
<err>
Write Command
AT^SRTC=
]
Response(s)
^SRTC:
OK
ERROR
+CME ERROR:
<err>
PIN
Last
-
+
-