2.8 AT+CFUN
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 40 of 513
6
This mode was implemented in EHS6 Release 1 for activating the
USAT
inter-
face. As of EHS6 Release 2 the mode is deprecated and no longer effective.
USAT
can now be used in Automatic or Explicit Response Mode depending on
settings.
7
Reserved for future use.
8
Reserved for future use.
Parameter
applies only to
1 and 4.
[0]
ME switches to
level without reset.
1
ME resets and restarts to full functionality level or Airplane mode, depending
on given
value. "
" URC indicates that the ME is ready to
operate.
Note: Autobaud mode (see
) requires an "AT" or "at" string be given
after restart. This enables the ME to detect the bit rate set in the TE. After
detecting the bit rate the ME will send the "
1
ME is switched on
2
Invalid mode
4
Airplane mode
0
Deprecated. See above
value 6.
6
Deprecated. See above
value 6.
7
Reserved for future use.
8
Reserved for future use.
<rst>
(num)
<power_mode>
(num)
<STK_mode>
(num)