Cinterion
®
EHS6 AT Command Set
7.22 ATS7
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 162 of 513
7.22
ATS7 Set number of seconds to wait for connection completion
is implemented for compatibility reasons only, and has no effect.
Syntax
Parameter Description
000...060
(&F)
Notes
• Command
is dummy, and has no effect on module behavior.
• Values greater than 60 (maximum 255) cause no error, but
will be restored to the maximum value of 60.
• Read command will return value written by user or default value n=60.
• Write command will return OK or ERROR. OK - when parameter
is in range, ERROR otherwise.
• Despite OK returned in case of any parameter from range, no changes will be made.
• Parameter is volatile.
Read Command
ATS7?
Response(s)
OK
Write Command
ATS7=
Response(s)
OK
ERROR
PIN
Last
Reference(s)
-
+
-
ITU-T V.250
<n>
(num)(&V)(&W)