![Gemalto Cinterion EHS6 Command Manual Download Page 91](http://html.mh-extra.com/html/gemalto/cinterion-ehs6/cinterion-ehs6_command-manual_2206684091.webp)
Cinterion
®
EHS6 AT Command Set
3.2 AT^SIND
EHS6_ATC_V03.001
15/12/3
Confidential / Released
Page 91 of 513
Unsolicited Result Codes
URC 1
Format of the standard indicator:
+CIEV:
Value of an indicator has changed.
URC 2
Format of the "simdata" indicator:
+CIEV:
This URC is issued indicating that the content of one or more USIM Elementary Files has been changed.
URC 3
Format of the "vmwait" indicator:
+CIEV:
The URC is issued after receiving an SMS with message waiting indicator included in User Data Header
(UDH).
URC 4
Format of the "eons" indicator:
+CIEV:
One URC is issued for each new LAI (Location Area Information) broadcast by the network.
URC 5
Format of the "nitz" indicator:
+CIEV:
URC 6
Format of the "lsta" indicator:
In case
equals "0" or
equals "2".
+CIEV:
The URC is issued for every radio link error. It provides the error downcounter value corresponding to number
of consecutive errors on downlink and the RSSI of the serving cell.
Error downcounter value of 11 corresponds to first error occurred on downlink, 0 corresponds to last before
cell loss. If module retrieves registration after jamming disappears, this URC will also be issued once to indi-
cate the recovery, with
set to 1.
Write Command
AT^SIND=
"lsta",
[,
]
Response(s)
^SIND:
"lsta",
[,
]
OK
ERROR
+CME ERROR:
<err>
PIN
Last
-
+
-