162
13. ANNEXES
80703B_MHW_2850T/3850T_02-2019_ENG
Type
Group
Variable name
Use
Description
Boolean System START_ZERO
R W Start program ZERO
Boolean System RESET_
n
R W
Reset program
n.
The status switches to READY (STATUS_n = 0)
n
can take on values from 1 to 8.
Boolean System RESET_ZERO
R W Reset program ZERO
Boolean System PAUSE_
n
R W
Pause program
n.
The status switches to HOLD (STATUS_n = 2)
n
can take on values from 1 to 8.
Boolean System END_
n
R W
End program
n.
The status switches to END (STATUS_n = 3)
n
can take on values from 1 to 8.
Boolean System SKIP_
n
R W
From the HOLD condition, program n passes to the following segment
n
can take on values from 1 to 8.
Boolean System WAIT_
n
R
Waiting for the consents before executing the step of program n.
n
can take on values from 1 to 8.
Boolean System CH
n
_ALL_H
R
Top range exceeded alarm for channel
n
in the program in position 1.
n
can take on values from 1 to 4.
Boolean System CH
n
_ALL_H_P
p
R
Top range exceeded alarm for channel
n
in the program in position
p
.
n
can take on values from 1 to 4.
p
can take on values from 2 to 9.
Boolean System CH
n
_ALL_L
R
Bottom range exceeded alarm for channel
n
in the program in position
1.
n
can take on values from 1 to 4.
Boolean System CH
n
_ALL_L_P
p
R
Bottom range exceeded alarm for channel
n
in the program in position
p
.
n
can take on values from 1 to 4.
p
can take on values from 2 to 9.
Boolean System WAIT_DISABLE_
n
R W
Disable waiting for consent in the program step
n
.
n
can take on values from 1 to 8.
Boolean System HBB_
n
R
HBB alarm for program
n
.
n
can take on values from 1 to 8.
Boolean System START_ENABLE
R W
Indicates the possibility to start the program. You can reset it to prevent
the programs from starting.
Boolean System SUSPEND_n
R W
Suspends program
n
.
n
can take on values from 1 to 8. Works like the PAUSE command,
but status is not changed and as soon as the SUSPEND signal is OFF
again, the program automatic restarts.
Boolean System SUSPEND
R W Suspends all programs
Boolean System MANUAL_SEL_
n
R W
Program n command in manual mode, valid only when the program is
in READY status, i.e. not being executed.
n
can take on values from 1 to 8.
Ret
Register
System MANUAL_SPm_n
RW Set the manual SP of profile m in program n
String
System Program_
n
_name
R
Program name
n
.
n
can take on values from 1 to 8.
String
System Program_
n
_descr
R
Program n description
n can take on values from 1 to 8.
String
System WORK_NAME_
n
R W
Program batch name
n
.
n
can take on values from 1 to 8.
String
System TIME_STEP_n
R
Time missing to the subsequent step of program n
String
System TIME_INC_n
R
Total time from the Program n START
String
System POWER_ON
R
Start text: "Power on".
String
System POWER_OFF
R
Stop text: "Power off".
String
System PROGRAM_STOP
R
Idle program text: "Program ready".
String
System PROGRAM_START
R
Running program text: "Program run".
String
System PROGRAM_HOLD
R
Paused program text: "Program hold".
String
System PROGRAM_END
R
End program text: "Program end".
String
System PROGRAM_SKIP
R
Skip program text: "Program skip".
String
System
PROGRAM_STEP_
TIME
R
Time until next step for program in 1
st
position.
NB:
The 09 program index corresponds to the TEMPLATE program.
The 10 program index corresponds to the ZERO program.
Summary of Contents for 2850T
Page 2: ......
Page 6: ...80703B_MHW_2850T 3850T_02 2019_ENG 4...
Page 10: ...80703B_MHW_2850T 3850T_02 2019_ENG 8...
Page 20: ...80703B_MHW_2850T 3850T_02 2019_ENG 18...