Chapter 4 Software Index
4-19
14- Motor Auto-Tune Parameters
Function
Code No.
LCD
Display
Description
Range/Code
Factory
Setting
Remarks
14-0
(Stator Resistor)
Stator Resistance (Ohms)
-----
*3*5
14-1
(Rotor Resistor)
Rotor Resistance (Ohms)
-----
*3*5
14-2
(Equi Inductance) Equivalent Inductance (mH)
-----
*3*5
14-3
(Magnet Current)
Magnetizing Current (Amps
AC)
-----
*3*5
14-4
(Ferrite Loss)
Ferrite Loss Conductance (gm) -----
*3*5
15- Drive Status and Function Reset
Function
Code No.
LCD
Display
Description
Range/Code
Factory
Setting
Remarks
15-0
(Drive Model)
Drive Horsepower Code
(See page 4-53)
*3
15-1
(Software Version) Software Version
-----
-----
*3
15-2
(Fault Log)
Fault Jog (Last 3 Faults)
(See page 4-53)
-----
*3
15-3
(Elapsed Hours)
Accumulated Operation Time
(Hours)
0 - 9999
-----
*3
15-4
(Elapsed Hr*10000)
Accumulated Operation Time
(Hours X 10000)
0 - 27
-----
*3
15-5
(Elapsed Time Sel)
Accumulated Operation Time
Mode
0000: Time Under Power
0001: Run Mode Time Only
0000
*3
15-6
(Reset Parameter) Reset Drive to Factory Settings
1110: Reset for 50 Hz Motor
Operation
1111: Reset for 60 Hz Motor
Operation
1112: Reset PLC Program
0000
*4
※
Notes: *1 can be modified during operation
*2 cannot be modified during communication
*3 do not change while making factory setting
*4 as parameter related to factory setting
*5 the parameter will be changed by replacing model (see descriptions of the
POSTSCRIPT 1)
*6 only available in V/F mode
*7 only for version 2.3 and above.