Chapter 4 Software Index
4-9
0- Drive Operation Mode
Function
Code No.
LCD Display
Description
Range/Code
Factory
Setting
Remarks
0-00
(Control Mode)
Control Mode
0000: Vector (General Purpose)
0001: Vector (Variable Torque)
0002: Volts/Hz (Refer to Parameter
Group 10- Volts/Hz Mode)
0000
*3
0-01
(Motor Rated Volt) Motor Rated Voltage (Vac)
-----
*3*5
0-02
(Motor Rated Amp) Motor Rated Current (Amp)
-----
*3*5
0-03
(Motor Rated KW) Motor Rated Power (kW)
-----
*3*5
0-04
(Motor Rated RPM) Motor Rated Speed (RPM)
X100*7
-----
*3*5
0-05
(Motor Rated Hz) Motor Rated Frequency (Hz)
-----
*3*5
0-06
(Auto Tuning)
Motor Parameter Auto Tuning
0000: Invalid
0001: Valid
0000
0-07
(AC Input Volt)
AC Line Input Voltage (Vac)
220V SERIES
:
170.0~264.0
440V SERIES
:
323.0~528.0
*3
0-08
(Select Language) Language Selection
0000: English
0001: German
0002: French
0003: Italian
0004: Spanish
0000
Only for
LCD
keypad
1- Start/Stop and Frequency Control Modes
Function
Code No.
LCD Display
Description
Range/Code
Factory
Setting
Remarks
1-00
(Run Source)
Run Command Source Selection
0000: Keypad
0001: External Run/Stop Control
(See 1-01)
0002: Communication
0003: Built-In PLC
0000
1-01
(MFIT Run Mode)
Run/Stop-Forward/Reverse
Operation Mode with External
Terminals
0000: Forward/Stop-Reverse/Stop
0001: Run/Stop-Forward/Reverse
0002: 3-Wire Control Mode-
Run/Stop
0000
1-02
(Reverse Oper)
Prohibition of Reverse operation
0000: Enable Reverse Command
0001: Disable Reverse Command
0000
1-03
(Keypad Stop)
Keypad Stop Button
0000: Stop Button Enabled
0001: Stop Button Disabled
0000
1-04
(Starting Method) Starting Method Selection
0000: Normal Start
0001: Enable Speed Search
0000
1-05
(Stopping Method) Stopping Method Selection
0000: Controlled Deceleration-to-
Stop with DC Injection
Braking (Rapid Stop)
0001: Free run Stop