20
MDS entraNET Technical Manual
05-4055A01, Rev. E
Invisible place holder
Figure 2-4. Power Connector
(polarity: left +, right –)
The transceiver must be used only with nega-
tive-ground systems. Make sure the polarity of the
power source is correct. The radio is protected from
reverse polarity by an internal diode and an on-board
fuse.
Power Supply
Connections at
28 Vdc
Common 28 Vdc supplies are often high-current power supplies
designed primarily to charge battery banks. The radio can be operated
from these supplies, providing there are no transients on the leads as
power is applied to the radio. Transients can be created that rise above
30 Vdc to a voltage that exceeds the primary voltage rating of the radio
and can destroy its voltage regulators and other components. It is
important to keep this potential hazard in mind when designing 28 Vdc
power supply connections for the radio.
• Use a two-conductor cable to power to the radio. Then the
currents in the positive and negative wires are equal and
opposite, causing their magnetic fields to cancel. The result is
no net inductance in the connection to cause voltage overshoot.
• Do not connect a radio to a power supply that is already
powered up, unless necessary (that is, when connecting a radio
to a battery bank and charger). When power is applied by
switching on a power supply, the rise time of the supply is too
slow to cause overshoot.
• Typically, there are multiple return paths for the negative side
of the power supply, through the coaxial cable shield and the
chassis, for example. Any imbalance in the currents in the
power cable results in voltage overshoot, so this should be
minimized during initial power-up if the supply cannot be
turned off.
• Add a 1 to 2
, 2 W resistor in series with the positive lead. This
greatly limits voltage overshoot. Since these radios draw very
little current in receive mode, and transmit only briefly, there is
little loss in power efficiency. In transmit, the voltage drop is
minimal and has no effect.
Wire Ports
Lead
Screws (2)
Binding
POSSIBLE
EQUIPMENT
DAMAGE
CAUTION
POSSIBLE
EQUIPMENT
DAMAGE
Summary of Contents for MDS entraNET 2400
Page 10: ...LA N CO M1 CO M2 PW R LIN K viii MDS entraNET Technical Manual 05 4055A01 Rev E ...
Page 12: ...2 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 24: ...14 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 26: ...16 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 38: ...28 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 110: ...100 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 130: ...120 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 156: ...146 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 158: ...148 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 176: ...166 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 186: ...176 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 188: ...178 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 204: ...194 MDS entraNET Technical Manual 05 4055A01 Rev E LA N CO M1 CO M2 PW R LIN K ...
Page 218: ...I 8 MDS entraNET Technical Manual 05 4055A01 Rev E ...