GASBOY Series 1000
8-8
05/29/03
Sometimes, when a pump is not operating properly, fuel can be dispensed but not recorded. This
is known as a no quantity transaction. You can set a system configuration parameter to
automatically disable a pump after a set number of consecutive no quantity transactions.
Typically, the number of no quantity transactions is configured to 3 or 5 but values can range from
1-99. If a pump becomes disabled in this manner, the PUMP # _ DISABLED message appears
on the direct printout as shown below. The pump remains disabled until you enable the pump
using the EP command.
86%2'%6()14:),(%8)8-1)44659%28-8=3(31)6636
4914(-7%&0)(