CFN Series System
4-2
03/07/03
2.
Remove the six screws from the two upper side pedestal covers. Unlock and remove
covers. Remove the four screws from the lower pedestal cover(s) and remove cover(s) from
the pedestal. The lower cover(s) will still be attached to the pedestal by a grounding wire and
tether.
3.
Verify that the conduit and all system, pump, and dispenser wiring is installed according to
the specifications detailed in the
Islander Installation Manual
. Non-compliance with these
specifications and the checks in the accompanying Start-Up Form could void the warranty.
ISLAND CARD READER ASSEMBLY
1.
Verify that the island card reader is installed to allow adequate clearance for system
maintenance. For systems with receipt printers or pedestal pump controls, a minimum of 18
inches is required between the post and any of the pumps or dispensers. This clearance
meets the NFPA 30A and NFPA 70 requirements.
2.
Remove the two tamper-proof screws from either side of the black bezel, located on the front
of the island card reader head assembly. Unlock and lower the black bezel door.
3.
Remove the six screws from the lower back side pedestal cover and remove the cover.
NOTE:
No AC power should be present at TB6 in the island card reader head assembly.
4.
Verify that the conduit and all system, pump, and dispenser wiring is installed according to
the specifications detailed in the
Site Controller II
or
Islander II Installation Manual
. Non-
compliance with these specifications and the checks in the accompanying Start-Up Form
could void the warranty.
PUMP CONTROL UNIT(S)
1.
Verify that the pump control unit(s) are installed in an area protected from direct contact with
the weather according to the
Site Controller II or Islander II Installation Manual
.
2.
Verify that the conduit and all system, pump, and dispenser wiring is installed according to
the specifications detailed in the
Site Controller II or Islander II Installation Manual
. Non-
compliance with these specifications and the checks in the accompanying Start-Up Form
could void the warranty.
✍
7. CONDUIT
All Metal Conduit:
Indicate if all conduit is metal and not PVC. Circle
Y
for
yes (all metal) or
N
for no (not all metal conduit).
AC and DC in Separate Conduit:
Indicate if all wiring is separated in the appropriate
conduits according to the conduit specifications and
exceptions detailed in the appropriate
Installation
Manual
. Circle
Y
for yes if all AC and DC wiring is in
separate conduits. Circle
N
for no if AC and DC wiring
is combined in conduits where it should not be.
Summary of Contents for CFN Series
Page 1: ...CFN SERIES SITE CONTROLLER II ISLANDER II START UP MANUAL C01665 GASBOY INTERNATIONAL LLC ...
Page 2: ......
Page 8: ...CFN Series System Contents 4 03 07 03 ...
Page 24: ...CFN Series System 2 12 03 07 03 ...
Page 25: ...Site Information 03 07 03 2 13 ...
Page 26: ...CFN Series System 2 14 03 07 03 ...
Page 38: ...CFN Series System 4 6 03 07 03 ...
Page 56: ......
Page 58: ......
Page 72: ......
Page 82: ...CFN Series System 9 10 03 07 03 ...
Page 104: ...CFN Series System 12 12 03 07 03 ...
Page 108: ...CFN Series System 13 4 03 07 03 ...