14
Command 46
Follow-On Mode & Two-Way Period
z
This command is used to program the
allowable time duration for Follow-On
mode choice (Commend #45) & Two-way
voice communication period (Speech
mode). It can be set from (
01
) (1 minute) -
(
10
) (10 minutes).
Function Selection
Result
(01) 1
MINUTE
(02) 2
MINUTES
(03)-(10)
3-10 MINUTES
z
Factory default is set as (
02
) 2 minutes.
The allowable time duration for either
Wait
Command
,
Two-way
,
Listen-In Only
or
Two-way voice comminucation
in
Speech mode
is two mins. During the 2-
min period, CTC-1052RV will emit two
beeps via the telephone handset to alert
the call recipient the remaining time of 20 &
10 secs. Pressing assigned DTMF key can
extend another 1-10 minute(s).
Command 47
Off-Set Time
z
After the Control Panel‘s power is supplied,
the time of the Check-in Report starts
calculating.
z
According to the setting of Off-Set Time,
the Control Panel will send Check-in
Report once, and then send report
according to the setting of Command 43
-
Test call.
Function
Selection
Result
(1) 1
Hour
(2) 2
Hour
(3) 3
Hour
(4)
4 Hour
(5)
8 Hour
(6) 12Hour
z
Factory default is set as (
1
) 1 Hour. When
the
Off-Set Time
is reset in programming
Mode, the time of the Off-Set period will
recalculate.
z
Off-Set time Report will be sent only once,
and then the Control Panel sends Check-in
Report according to setting of period test
call, unless the Control Panel restarts or
the Off-Set time is reset.
<
<
N
N
O
O
T
T
E
E
>
>
)
Whenever programming mode is
accessed, CTC-1052RV will reset the
Off-Set timer.
Command 49
Supervision
This function is not available for the digital
Scancom reporting method.
z
This option is used to enable system
Supervision function. Once enabled, CTC-
1052RV will be able to receive the check-
in signals from Wrist Pendants (WTR-) to
indicate their proper functioning.
Function
Selection
Result
(0) Disable
(1) 4
Days
(2) 5
Days
(3) 6
Days
(4)
7 Days
(5)
8 Days
(6) 9
Days
(7) 10
Days
z
Factory default is set as (
0
)
Disable
. No
code is sent to Monitoring Center.
z
When the supervisory timer expires and no
supervision signal is received from WTR-,
the supervisory alarm reporting will be
made.
z
The reporting method for supervisory alarm
is the same as the emergency alarm. The
report will be sent based on your reporting
methods without guard time waiting.