12
section
4.2. Alarm Activation
.
)
The Access Code must be entered
within 15 secs. Otherwise, CTC-
1052RV will disconnect the call
automatically.
)
To terminate the call, press DTMF (
9
)
or RESET BUTTON on CTC-1052RV.
)
If the 5-minute waiting period is up,
CTC-1052RV will automatically exit
this waiting mode and return to idle
mode.
)
During the AC Power failure period,
Call-Back function is automatically
disabled.
Command 40
Set Access Code
z
The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
z
It consists of 4 digits and has been set to
(
1111
) as factory default. Before you set
your own Access Code,
(
1111
) must be
keyed in.
z
To set a new Access code; enter the
desired (
4-digit number)
in
Function
Selection
.
Command 42
Guard Time Delay
z
CTC-1052RV can be programmed to delay
alarm reporting from (
00
) (instant reporting)
to (
99
) seconds.
z
During this time period, a continuous series
of beeps will be emitted to alert user.
z
If a false alarm is triggered, it can be
cancelled within the Guard Time Delay.
Function
Selection
Result
(00) INSTANT
REPORTING
(01) - (99)
DELAY
z
Factory Default is (
10
),
10 SECONDS
.
<
<
N
N
O
O
T
T
E
E
>
>
)
Emergency alarm cannot be cancelled
after the Guard Time is elapsed.
Command 43
Periodic Test Call
z
CTC-1052RV can be programmed to make
test calls periodically from (00) (no test call)
to every (1) - (7) or 30 days:
Function Selection
Result
(0) OFF
(1) - (7)
1 - 7 DAYS
(8) 30
DAYS
z
Factory Default is set as (
0
),
OFF
.
<
<
N
N
O
O
T
T
E
E
>
>
)
Whenever programming mode is
accessed, CTC-1052RV will reset the
Periodic Test Call timer.
Command 44
Mobility Timer
This function monitors user movement around
the premises and sends an inactivity report to
the Monitoring Center if the user fails to reset
the inactivity timer.
z
This will disable or enable the Inactivity
Timer with selectable count down periods.
Options are:
Function
Selection
Result
(00)
DISABLE
(01) 1HR
(02) 2HR
..........
.........
Summary of Contents for CTC-1052RV