13
(36) 36HR
z
Factory Default is set as (
00
),
DISABLE
.
<
<
N
N
O
O
T
T
E
E
>
>
)
The Mobility Timer counting down can
be reset by:
1. Pressing the
RESET
button on
CTC-1052RV, or,
2. Movement detected by PIR
Detector
3. Only workable by entering 2 digits.
)
When Mobility Timer expires and no
reset signal is received, CTC-1052RV
starts to emit one long beep every 5
minutes to alert the user. After 30
minutes, if reset signal is not received,
a mobility alarm reporting will be made.
)
The reporting method for mobility alarm
is the same as the emergency alarm.
The report will be sent based on your
reporting methods without guard time
waiting.
)
When (
00
) is selected, no code is sent
to Monitoring Center.
)
When CTC-1052RV is in idle mode,
press and hold the green reset button
for 16 seconds, until you hear a long
beep. Then release the button; the
Mobility function will be disabled.
Command 45
Follow-On Mode Choice
z
This Command is only available for Digital
reporting with Command #38
set as (
0
) or
(
2
).
z
It is used to select the Follow-On Choice
for CTC-1052RV after it has made a report
to the Monitoring Center.
z
After reporting, CTC-1052RV can wait for
further commands, or enter a Two-Way
Full Duplex Communication, or Listen-In
Half Duplex Communication immediately
according to the setting under this
command:
Function
Selection
Result
(0)
WAIT
COMMAND
(1) LISTEN
(2) TWO
WAY
z
Factory Default is
set
as (
2
)
, TWO WAY
.
<
<
N
N
O
O
T
T
E
E
>
>
)
When (
0
)
is selected, after CTC-
1052RV has made an alarm report to
the Monitoring Center, it will wait for 1-
10 minutes (set by Cammand 46
),
and
then follows the DTMF commands that
are received from the Central
Monitoirng Station for action.
If no command is received after the
waiting period, the system will
automatically return to Idle mode.
)
When (
1
)
is selected, after CTC-
1052RV has made a report to the
Monitoring Center, it will automatically
enter
Listen-In Half Duplex
for 1-10
minutes (set by Command 46) allowing
the Monitoring Center Personnel to
listen in to what is happening on the
other side.
)
When (
2
) is selected, after CTC-
1052RV has made a report to the
Monitoring Center, it will immediately
enter a
Two-way Full-duplex
Communication
mode for 1-10
minutes (set by Command 46), that
gives the user the ability to speak
directly with the Monitoring Center
Personnel.
)
If either Scancom or Tunstall reporting
format is selected, CTC-1052RV will
ignore Command #45 selections. It will
always open a Two-way voice for
Follow-On choice.
)
If an alarm is triggered by
WTRV/WTRVS, the Monitoring
Center personnel has to press the
DTMF 2 over 1 second to open the
two-way communication between
WTRV/WTRVS no matter what
Follow-On choice you have set.