AC Fault Report
z
The CTC-1052RV can be programmed to
send a Fault Report when an AC power
failure is detected.
Function Selection
Result
(0)
OFF
(Send No Report)
(1)
ON
(Send Report)
z
Factory
Default
is set as (
1
),
ON
.
<
<
N
N
O
O
T
T
E
E
>
>
)
Reporting will only be made after a
continuous one hour of AC Fault
condition is detected.
Command 38
Follow-On & Call-Back Function
z
The Command is available for Digital
Reporting Methods (when Command #20 -
#24 is set as (0), (1) or (2))
Function Selection
Result
(0) Follow-On
(1) Call-Back
(2)
Follow-On & Call-Back
z
Factory Default
is
as
(0), Follow-On
.
z
When this function is programmed as (
0
),
after a successful alarm reporting
(triggered by pressing the Help button on
the Medical Panel) to the Monitoring
Center, CTC-1052RV will automatically
enter the Follow-On mode as specified by
Command (
45
).
If the alarm is triggered by
a Talking Pendant (WTRV/WTRVS), the
system will automatically enter to the “Wait
for Command” mode (skips to check
Command
45
) and wait for the DTMF 2
signal pressed by the Monitoring Center to
set up the two-way communication
between WTRV/WTRVS and the
Monitoring Center.
z
When this function is programmed as (
1
),
after a successful alam reporting (triggered
by pressing the Help button on the Medical
Panel) to the Monitoring Center, CTC-
1052RV will automatically hang up the line
and start a 5-minute waiting period to auto
answer any incoming phone calls from the
Monitoring Center. The Monitoring Center
personnel should enter an authorized
access code (default: 1111), followed by (#)
to set up the two way communication
between CTC-1052RV and the Monitoring
Center.
If the alarm is triggered by a Talking
Pendant (WTRV/WTRVS), during the 5-
minute waiting period, the system will
wait for an authorized access code
(default:1111), followed by (#) to open the
two-way communciation between
WTRV/WTRVS and the Monitoring Center.
z
When this function is programmed as (
2
),
after a successful alarm reporting
(triggered by pressing the Help button on
the Medical Panel) to the Monitoring
Center, CTC-1052RV will automatically
enter the Follow-On mode as specified by
Command (
45
). If the alarm is triggered by
a Talking Pendant (WTRV/WTRVS), the
system will automatically enter the “Wait
for Command” mode (skips to check
Command
45
) and wait for the DTMF 2
signal pressed by the Monitoring Center to
set up the two-way communication
between WTRV/WTRVS and the
Monitoring Center.
Once Follow-On Mode is terminated, CTC-
1052RV will automatically start a 5-minute
waiting period to auto answer any incoming
phone calls from the Monitoring Center. The
Monitoring Center personnel should enter
an authorized access code (default: 1111),
followed by (#) to set up the two way
communication between CTC-1052RV and
the Monitoring Center. If the alarm is
triggered by a Talking Pendant
(WTRV/WTRVS), during the 5-minute
waiting period, the system will wait for an
authorized access code (default:1111),
followed by (#) to open the two-way
communciation between WTRV/WTRVS
and the Monitoring Center.
<
<
N
N
O
O
T
T
E
E
>
>
)
During two-way communication, you
can use DTMF command to switch the
communicating method. Please refer to
Summary of Contents for CTC-1052RV
Page 1: ...E1 MAR 30 2011...