ISO Preferred OA Dual Upright ROM Hinge Knee Brace (KN22xx) provides stability for treating mild injuries of the Collateral
ligaments, Menisci and Patellar retinaculum in addition to support and relief for Chronic knee pain or instability, Loose body in the
knee, Cartilage or Meniscus tears of the knee, Sprains and strains of the knee, and Old disruption of the anterior cruciate ligament.
ROM hinges have Extension/Flexion and Varus/Valgus control settings.
OA Dual Upright ROM Hinge Knee Brace
The
ISO Preferred OA Dual Upright ROM Hinge Knee Brace
provides a dual upright
support with ROM hinges for extension/flexion and Varus/Valgus knee control. Support
features reduce the time it takes to heal discomfort from injuries or post-surgery. Please
follow your orthopedic professional’s instructions explicitly and adjust or discontinue use
only as directed to achieve maximum benefit for your concerns.
Always Putting Our Patients First
1
. Loosen all closure straps, leaving the brace open. Fit the brace by applying to the knee for
which it was prescribed with the hinges on each side of the knee.
2. Apply to the front of the thigh and calf, lining up the hinges with the knee joint. Secure
the front straps on the thigh, then the calf. Secure the back straps on the thigh first and
then the calf. Each strap includes a gripping comfort cushion. Place the gripping comfort
cushion as desired for a secure and snug fit on all six (6) straps, to keep the brace in the
proper position.
Straps may be shortened by removing the advanced gripping end tab and cutting off
the excess strap.
If the fit is too small or too large, or hinges are not properly positioned, unfasten,
adjust and refasten. Place the adjusted brace on knee and confirm a snug fit.
DO NOT
OVERTIGHTEN
.
3.
ROM Hinge Adjustment:
Using the provided Screwdriver, loosen both screws on the
outer hinge cover. Per physician’s instructions, identify the correct Hinge Stops with
correct degree markers for the Flexion, Extension or both (see illustration below to
identify the hinge stops by markings on the back side of each). Insert the selected Hinge
Stop(s) into the correct side of the Hinge. Insert screws into holes and tighten until screw
top is flush with hinge plate cover. Repeat these instructions for the inner hinge cover.
4.
Unloading Adjustment:
Note: Physician guidance required for this adjustment. Using the
included Allen Wrench, rotate the unloading dial above the outer hinge cover clockwise
or counterclockwise to adjust hinge to desired angle. Repeat these instructions for the
unloading dial above the inner hinge cover.