8.10 Meaning of optocoupler settings "Rising_Edge", "Falling_Edge", "Rising- and Falling
Edge"?
Optocouplers are digital inputs used for status acquisition, for example if a turnstile or door, connected to the GAT
Access 6100, is closed or opened.
When set to "Rising_Edge" the terminal will send the "Action_Started" command in case the optocoupler is active (i.e.
current). When set to "Falling_Edge" the terminal will send the "Action_Started" command in case the optocoupler is
NOT active (i.e. no current). When set to "Rising- and Falling Edge" the terminal will send the "Action_Started"
command when the optocoupler is activated OR deactivated, depending which happens first.
8.11 How can the reader of a GAT Access 6100 B be authorized for LEGIC?
To authorize for LEGIC means that the GAT Access 6100 B reader is registered to be able to read and write segments
of LEGIC
data carriers (e.g. locker segments). Authorizing for LEGIC is only possible with a GAT Access 6100 B
terminal, because only this terminal has a built-in LEGIC reader.
The device can be registered in different ways:
a) During normal operation (while the terminal is in normal online mode) hold the authorization card (SM100 or SAM-
63 resp.) next to the scan field for approx. 30 seconds.
b) In the Service menu (see "5.3 System Settings") select "Reader" -> "Read UID" and then hold the authorization
card (SM100 or SAM-63 resp.) to the scan field for approx. 30 seconds until the UID number is shown on the
display.
c) With the "Enable_Authorisation" command of the FUNLINE protocol (see protocol manual) and an authorization
card (SM100 or SAM-63 resp.).
NOTE!
The value of the site key in the configuration must be the same as the one of the authorization card. In case
of problems also check the sub-site key and the groups.
8.12 How can I read or delete the authorization data of a GAT Access 6100?
The authorization data of a LEGIC GAT Access 6100 B reader can be read or deleted in different ways:
a) In the Service menu (see "5.3 System Settings") select "Reader" and in the next menu either "Read Authoris." or
"Delete Authoris." to show or delete the authorization data on the display. Note that if the authorization is deleted,
no further writing of LEGIC
®
data carriers is possible (e.g. for Locker Check-In).
b) With the "Read_Authorisation_Data" or "Clear_Authorisation_Data" command of the FUNLINE protocol (see
protocol manual).
8.13 How can I configure the display texts of a GAT Access 6100?
The display texts of a GAT Access 6100 are set by default, but can be changed with the GAT Config Manager software
(see "5.4.4 Display Texts
Summary of Contents for GAT ACCESS 6100
Page 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com ...
Page 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com ...
Page 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com ...