Device Licence
License to enable special features of the device, for
example for the GAT Access 6100 F Upgrade (see "5.5.
Configuration of Offline Emergency Mode for a GAT
Access 6100 ").
Hex
4895CA89…
Enrollment Station
Indicates, if the license activates the Enrollment Station
functionality
Boolean
false
Disable Secure UID
Indicates, if the license is used to deactivate the Secure
UID
Boolean
false
Offline Upgrade
If this licence is loaded, the terminal is able to check
flags from the data carrier
Boolean
false
Thirdparty Validation
Indicates, if the license is used for third party validation
Boolean
false
Enable GAT Shower
Indicates, if the countdown functionality is activated.
Boolean
false
Remaining period mode
Determines the action that will be performed after the
timeout during a remaining period break (see section
“Application” -> “Timeouts”) is exceeded. For this
function a special licence is required.
Cancel: The countdown process will be cancelled
Continue Relay off: The countdown will proceed, the
relay will be switched off
Continue Relay on: The countdown will proceed, the
relay will be switched on
Cancel
Continue Relay
off
Continue Relay
on
Third Party Write
Enable/Disable the Third Party Write function. In order
to use this function the corresponding licence is
required. If this license is loaded, the terminal allows the
writing of data from the management software directly to
the data carrier.
Boolean
false
Second Ident with Card
With this option it will be allowed to confirm the second
identification with the data carrier.
Boolean
true
Data handling
Deny if Checkin failed
Access denied if the LockerCheck-In fails
Boolean
false
Check validity date
Checks site number and validity date of data carriers,
when the GAT Access 6100 is in the Emergency Mode
Boolean
false
Locker 1
Read
Indicates, if data must be read from the first locker
segment of the data carriers.
Boolean
true
Position on card
Where the locker data 1 segment is located on data carriers
Integer
1 .. 255
Clear number
Clear the locker number from the data carrier.
Boolean
false
DESFire File Number
File number of the locker segment 1 on the data carriers
Integer
1
Start date
Mode
Selection of the LockerCheckin Mode for the Start Date
None: Value will not be changed
Delay: Sets the start date to now + start date value
Time: Sets the start date to today at start date value
Forever: Sets the start date to forever valid
Selection
None / Delay /
Time / Forever
Hours
Hours of start date
Integer
0 .. 23
Minutes
Minutes of start date
Integer
0 .. 59
End date
Mode
Selection of the LockerCheckin Mode for the End Date
None: Value will not be changed
Delay: Sets the expiry date to now + expiry date value
Time: Sets the expiry date to today at expiry date value
Forever: Sets the expiry date to forever valid
Selection
None / Delay /
Tiime / Forever
Hours
Hours of end date
Integer
0 .. 23
Minutes
Minutes of end date
Integer
0 .. 59