GAT Access 6100 Terminal Series
Operation
66
HB_GAT-ACCESS6100--EN_14
www.gantner.com
6.4
User Operation at a GAT Access 6100 / GAT Access 6100 F PoE
To gain access to a restricted area, the user holds their data carrier next to the scan field. The data carrier must be
held steadily in front of the scan field while the GAT Access 6100 reads the data carrier. Do not remove the data
carrier too early. First, the GAT Access 6100 checks the FID number (site number) on the data carrier. The FID of the
data carrier must be the same as the FID number of the terminal.
If the data carrier is valid (certificate, device license, FID), the GAT Access 6100 sends the data carrier information to
the host for evaluation with the stored personal data. If access to the restricted area is granted, a command is sent to
the GAT Access 6100 and the terminal will unlock the controlled door/turnstile for the configured time. The terminal
indicates whether access is granted or denied as shown below. Additionally, the four-segment LED display and the
RFID scan field illuminate green (access allowed) or red (access denied) with one (access allowed) or two (access
denied) acoustic signal(s) generated.
If the data carrier is not valid (e.g., not a GANTNER data carrier and certificate not deactivated via license), access is
also denied without further checking.
Figure 6.4 - Information display after reading a data carrier (access granted - green lights)
Figure 6.5 - Information display after reading a data carrier (access denied - red lights)