GAT Access 6100 Terminal Series
Electrical Connections
38
HB_GAT-ACCESS6100--EN_14
www.gantner.com
CAT 5 (STP) or higher Ethernet cable is recommended for a 100 MBit Ethernet connection.
Complete the network connections according to Ethernet standard 568A or 568B. The following wire colors are used
for the TX and RX contacts depending on which Ethernet standard is used:
568A
568B
TX+
green/white
orange/white
TX-
green
orange
RX+
orange/white
green/white
RX-
orange
green
Figure 4.5
– Wire termination colors for Ethernet cables
4.3.2
GAT Access 6100 F PoE
For the GAT Access 6100 F PoE, the Ethernet (PoE) cable connects to the RJ45 socket on the rear part of the GAT
Access 6100 F PoE housing as shown in Figure 4.2.
CAT 5 (STP) or higher Ethernet cable is recommended for a 100 MBit Ethernet connection. Terminate the cable
according to Ethernet standard 568A or 568B.
Summary of Contents for GAT ACCESS 6100
Page 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com ...
Page 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com ...
Page 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com ...