1. OPERATIONAL OVERVIEW
1-5
1.3.1
Lowering the transducer
With the boat at the fishing ground and the power on, press the or key. The lamp
above the key pressed blinks during lowering and lights when the transducer is com-
pletely lowered to selected protrusion distance. It takes about 21 seconds for full pro-
trusion in case of 800 mm stroke and 28 seconds in case of 1100 mm stroke. In normal
use fully lower the transducer. If the transducer becomes entangled in the net for some
reason, partially raise the transducer with the key. This raises the transducer by 300
mm.
1.3.2
Raising the transducer
Press the key to raise the transducer. The lamp above the switch blinks while the
transducer is being raised and lights steadily when it is fully raised.
1.4
Screen Brilliance, Panel Dimmer
1.4.1
Screen brilliance
The brilliance of an external monitor cannot be adjusted from the Control Unit. Use the
associated control on the monitor.
1.4.2
Panel dimmer
1. Press the
MENU/ESC
key to open the main menu.
2. Select [Others] then push the left-click button.