Specification
FM 28400
003
TI-117-J-DS-2015-8
Page 2 of 2
FM 28400
MODEL: J SERIES
UNIT
6J
8J
10J
15J
20J
30J
50J
60J
CE marked to PED, EMC & LVD, constructed to BS2790 as standard (other code specifications available).
General
Steam Output F & A 100 °C
kg/h
96
128
160
240
320
480
800
960
kW Rating
kW
60
80
100
150
200
300
500
600
Operating Pressure **
barg
10.34
10.34
10.34
10.34
10.34
10.34
10.34
10.34
Weight
Shipping Weight
kg
977
977
977
1090
1620
2270
3400
3400
Operational Weight
kg
1067
1067
1067
1290
1910
2910
4420
4420
Water Content
L
90
90
90
200
290
640
1020
1020
Efficiencies
Gross
%
80
80
80
80
80
80
80
80
Net
%
89
89
89
89
89
89
89
89
Gas Pressures
Min. Natural Gas Modulating***
mbar
-
-
-
-
-
30
30
30
Min. Natural Gas On/Off
mbar
18
18
18
18
18
18
18
18
Max. Natural Gas
mbar
100
100
100
100
100
100
100
100
Min. LPG
mbar
50
50
50
50
50
50
50
50
Max. LPG
mbar
80
80
80
80
80
80
80
80
Firing Rate
Gas ****
m
3
/h
7.0
9.3
11.6
17.4
23.2
34.8
58.1
69.6
Oil
L/h
7.1
9.4
11.8
17.6
23.6
35.2
58.9
70.4
LPG/Propane
m
3
/h
2.9
3.9
4.8
7.2
9.6
14.4
24.1
28.9
Ventilation Requirements for Combustion Purposes (Free Area)
Low Level inlet
cm
2
670
800
920
1250
1570
2220
3530
4170
High Level Outlet
cm
2
335
400
460
625
785
1110
1765
2085
Electrical Requirements
FLC 400 V 3 ph 50 Hz
A/ph
4.7
4.7
4.7
4.7
4.9
4.9
6.9
6.9
FLC 230 V 1 ph 50 Hz
A
12.7
12.7
12.7
12.7
14.9
-
-
-
Connection Sizes
All threads BSP
F= Female, M=Male
Steam Outlet
DN
20 F
20 F
25 F
32 F
32 F
40 F
50 F
50 F
Safety Valve Discharge
DN
25 F
25 F
25 F
25 F
25 F
25 F
32 F
32 F
Feedwater Inlet
DN
15 F
15 F
15 F
15 F
15 F
15 F
15 F
15 F
Feedwater Pump Inlet
DN
25 F
25 F
25 F
25 F
25 F
25 F
25 F
25 F
Blowdown, Boiler
DN
20 F
20 F
20 F
20 F
25 F
25 F
25 F
25 F
Blowdown, Water Column
DN
20 F
20 F
20 F
20 F
20 F
20 F
20 F
20 F
Blowdown, Water Level Gauge
(Sight Glass)
DN
15 F
15 F
15 F
15 F
15 F
15 F
15 F
15 F
Blowdown, TDS
DN
15 F
15 F
15 F
15 F
15 F
15 F
15 F
15 F
Water Sample Outlet
DN
15 M
15 M
15 M
15 M
15 M
15 M
15 M
15 M
Flue Outlet
in.
6
6
6
8
10
12
12
12
Gas Inlet
DN
20 F
20 F
20 F
32 F
32 F
40 F
50 F
50 F
Oil Connection
in.
Flexible hoses provided 1/4 in. BSP all models.
** Boilers at higher pressure, available to special order.
*** Modulating control available at lower gas pressures, to special order.
**** Natural Gas - Group H.
Summary of Contents for J Series
Page 2: ...JGASUK IOMM 2015 2 Fulton Ltd Page II ...
Page 54: ...JGASUK IOMM 2015 2 Fulton Ltd Page 48 APPENDIX A ...
Page 58: ...JGASUK IOMM 2015 2 Fulton Ltd Page 52 APPENDIX A ...
Page 60: ...JGASUK IOMM 2015 2 Fulton Ltd Page 54 ...
Page 62: ...JGASUK IOMM 2015 2 Fulton Ltd Page 56 ...